一、Panel cannot give a alarm phone call
Analysis
1.no arming
2.not set alarm phone
3.installation distance is too far away from the wireless detectors
4.not enroll wireless accessory
Solutions
1.to arm
2.to reset alarm phone
3.to adjust detectors’ installation site
4.to enroll again
二、Remote controller doesn’t work
Analysis
1.not enroll remote controller
2.low battery power
Solutions
1.to enroll again
2.to charge the battery
三、One long “Di”/15s and it shows low power in one of zones
Analysis
1.low battery power of wireless detector
Solutions
1.to change the battery
四、Wireless detectors are often triggered wrongly
Analysis
1.the installation site doesn’t conform with right condition
Solutions
1.to change a right installation site
五、It doesn’t call or send SMS to users when alarm happens
Analysis
1. not insert SIM card
2.weak GSM signal
3.copper sheet of SIM card is scratched
4. not set alarm number
5. no enough amount of SIM card
Solutions
1.insert SIM card
2.change to a place with strong GSM signal
3.change a new normal SIM card
4.reset alarm number
5.charge SIM card’s account
六、No any recording prompts when alarm happens
Analysis
1.not record alarm voice 1.to record the alarm voice again
Wired siren doesn’t work
1.bad contact
2.wrong connect with polarity
Solutions
1.connect again
2.connect BELL to positive side ,GND to negative side
七、Panel always shows zone faults
Analysis
1.wrong connection or bad connection
2.zone does not connect with 2.2k resistance when setting zone triggered way as end of line
Solutions
1. check up whether screw are tightened or not
2.connect a 2.2 resistance in the zone interface
八、Panel does not prompt when user dials to panel
Analysis
Ring bell function is closed
Solutions
Open ring bell function